Friction testing machine

  • High Frequency Reciprocating Friction and Wear Tester (Diesel Lubrication Performance Evaluation Tester)
High Frequency Reciprocating Friction and Wear Tester (Diesel Lubrication Performance Evaluation Tester)

High Frequency Reciprocating Friction and Wear Tester (Diesel Lubrication Performance Evaluation Tester)

  • Model: MGW-001
  • Product description: High Frequency Reciprocating Friction and Wear Tester (Diesel Lubrication Performance Evaluation Tester)
  • INQUIRY

Application

The high frequency reciprocating friction and wear tester can evaluate the lubricity of diesel oil (including diesel oil containing lubricants) under the condition of high frequency reciprocation. It can also be used to test the lubricating performance of lubricating oil and grease, and to measure the thickness of the oil film.

Technical Parameters

1. Reciprocating frequency: 10 ~ 200Hz; accuracy 1Hz

2. Reciprocating stroke: 2.5mm; accuracy 0.001mm

3. Temperature: room temperature ~ 200 ° C; accuracy 3 ° C

4. Load: 0.1 ~ 1kg

5. Maximum friction: 30N

6. Test ball: Diameter 6mm, 28 grade ANSIE-52100 steel which meets ANSIB3.12 standard, HRC of Cr hardness is 58-66, surface roughness Ra <0.05μm

7. Test piece: Round steel processed, in accordance with ANSIE-52100 standard, Vickers hardness "HV30" grade value is 190-210, surface roughness Ra <0.02μm

8. Oil bath area: 600 ± 100mm2

9. Wear scar measurement system: electron microscope, magnification 100 times, graduation 1μm

10. Constant temperature and humidity box:

Temperature control range: 17 ~ 30 ° C, temperature display accuracy 0.1 ° C, temperature control accuracy ± 2 ° C

Humidity control range: 20 ~ 70%, humidity display accuracy 1%, humidity control accuracy ≤3% RH

11. Ambient temperature: 5 ~ 35 ° C

12. Humidity: 20-80%

Test condition

1. Reciprocating displacement / mm: 1.0 ± 0.02

2. Reciprocating frequency / Hz: 50 ± 1

3. Applied load / g: 200 ± 1

4. Oil sample volume / ml: 2 ± 0.2

5. Oil sample temperature / ° C: 60 ± 2

6. Test time / min: 75 ± 0.1